Technical specifications

Voltage typeAC
Number of protected poles2
Current limiting class3
Rated insulation voltage Ui690V
Frequency50 - 60Hz
Rated current20A
Over voltage category3
Pollution degree3
Width in number of modular spacings3
Built-in depth82.5mm
Rated voltage400V
Degree of protection (IP)IP20
Release characteristicK
Connectable conductor cross section solid-core0 - 50mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Rated impulse withstand voltage Uimp8kV
Suitable for flush-mounted installationNo
Ambient temperature during operating-25 - 60°C
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Connectable conductor cross section multi-wired0 - 70mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Number of poles (total)2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Concurrently switching neutral conductorNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS862001R0487 | S802S-K20

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC

Number of protected poles

2

Current limiting class

3

Rated insulation voltage Ui

690V

Frequency

50 .. 60Hz

Rated current

20A

Over voltage category

3

Pollution degree

3

Width in number of modular spacings

3

Built-in depth

82.5mm

Rated voltage

400V

Degree of protection (IP)

IP20

Release characteristic

K

Connectable conductor cross section solid-core

0 .. 50mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Rated impulse withstand voltage Uimp

8kV

Suitable for flush-mounted installation

Ambient temperature during operating

-25 .. 60°C

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Connectable conductor cross section multi-wired

0 .. 70mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Number of poles (total)

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Concurrently switching neutral conductor

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.