Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Rated current63A
Release characteristicC
Rated voltage400V
Rated impulse withstand voltage Uimp8kV
Rated insulation voltage Ui690V
Number of protected poles2
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Frequency50 - 60Hz
Voltage typeAC
Current limiting class3
Degree of protection (IP)IP20
Over voltage category3
Concurrently switching neutral conductorNo
Built-in depth82.5mm
Connectable conductor cross section multi-wired0 - 70mm²
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Pollution degree3
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section solid-core0 - 50mm²
Width in number of modular spacings3
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS862001R0634 | S802S-C63

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated current

63A

Release characteristic

C

Rated voltage

400V

Rated impulse withstand voltage Uimp

8kV

Rated insulation voltage Ui

690V

Number of protected poles

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Frequency

50 .. 60Hz

Voltage type

AC

Current limiting class

3

Degree of protection (IP)

IP20

Over voltage category

3

Concurrently switching neutral conductor

Built-in depth

82.5mm

Connectable conductor cross section multi-wired

0 .. 70mm²

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Pollution degree

3

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section solid-core

0 .. 50mm²

Width in number of modular spacings