Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current63A
Voltage typeAC
Built-in depth82.5mm
Rated voltage400V
Degree of protection (IP)IP20
Over voltage category3
Release characteristicB
Ambient temperature during operating-25 - 60°C
Current limiting class3
Number of protected poles2
Width in number of modular spacings3
Connectable conductor cross section multi-wired0 - 70mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Connectable conductor cross section solid-core0 - 50mm²
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Pollution degree3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Concurrently switching neutral conductorNo
Number of poles (total)2
Suitable for flush-mounted installationNo
Rated insulation voltage Ui690V
Rated impulse withstand voltage Uimp8kV
Additional equipment possibleYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS862001R0635 | S802S-B63

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

63A

Voltage type

AC

Built-in depth

82.5mm

Rated voltage

400V

Degree of protection (IP)

IP20

Over voltage category

3

Release characteristic

B

Ambient temperature during operating

-25 .. 60°C

Current limiting class

3

Number of protected poles

2

Width in number of modular spacings

3

Connectable conductor cross section multi-wired

0 .. 70mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Connectable conductor cross section solid-core

0 .. 50mm²

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Pollution degree

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Concurrently switching neutral conductor

Number of poles (total)

2

Suitable for flush-mounted installation

Rated insulation voltage Ui

690V

Rated impulse withstand voltage Uimp

8kV

Additional equipment possible

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.