  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui1000V
Built-in depth82.5mm
Number of poles (total)2
Voltage typeAC/DC
Rated voltage500V
Frequency50 - 60Hz
Additional equipment possibleYes
Current limiting class3
Connectable conductor cross section multi-wired0 - 70mm²
Ambient temperature during operating-25 - 60°C
Over voltage category3
Release characteristicB
Pollution degree2
Rated current13A
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V50kA
Number of protected poles2
Width in number of modular spacings2
Degree of protection (IP)IP20
Concurrently switching neutral conductorNo
Suitable for flush-mounted installationNo
Connectable conductor cross section solid-core0 - 50mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V50kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Rated impulse withstand voltage Uimp8kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS862001R1135 | S802S-UCB13

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui

1000V

Built-in depth

82.5mm

Number of poles (total)

2

Voltage type

AC/DC

Rated voltage

500V

Frequency

50 .. 60Hz

Additional equipment possible

Current limiting class

3

Connectable conductor cross section multi-wired

0 .. 70mm²

Ambient temperature during operating

-25 .. 60°C

Over voltage category

3

Release characteristic

B

Pollution degree

2

Rated current

13A

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

50kA

Number of protected poles

2

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Suitable for flush-mounted installation

Connectable conductor cross section solid-core

0 .. 50mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

50kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Rated impulse withstand voltage Uimp

8kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.