Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC/DC
Rated current10A
Built-in depth82.5mm
Rated voltage500V
Release characteristicK
Over voltage category3
Number of protected poles2
Pollution degree2
Rated insulation voltage Ui1000V
Width in number of modular spacings2
Degree of protection (IP)IP20
Current limiting class3
Concurrently switching neutral conductorNo
Suitable for flush-mounted installationNo
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V50kA
Rated impulse withstand voltage Uimp8kV
Connectable conductor cross section solid-core0 - 50mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V50kA
Number of poles (total)2
Connectable conductor cross section multi-wired0 - 70mm²
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Ambient temperature during operating-25 - 60°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS862001R1427 | S802S-UCK10

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC/DC

Rated current

10A

Built-in depth

82.5mm

Rated voltage

500V

Release characteristic

K

Over voltage category

3

Number of protected poles

2

Pollution degree

2

Rated insulation voltage Ui

1000V

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Current limiting class

3

Concurrently switching neutral conductor

Suitable for flush-mounted installation

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

50kA

Rated impulse withstand voltage Uimp

8kV

Connectable conductor cross section solid-core

0 .. 50mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

50kA

Number of poles (total)

2

Connectable conductor cross section multi-wired

0 .. 70mm²

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Ambient temperature during operating

-25 .. 60°C