  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Current limiting class3
Connectable conductor cross section solid-core0 - 50mm²
Over voltage category3
Rated current63A
Connectable conductor cross section multi-wired0 - 70mm²
Pollution degree2
Voltage typeAC/DC
Number of protected poles2
Width in number of modular spacings2
Degree of protection (IP)IP20
Built-in depth82.5mm
Frequency50 - 60Hz
Rated voltage500V
Rated insulation voltage Ui1000V
Concurrently switching neutral conductorNo
Suitable for flush-mounted installationNo
Release characteristicK
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V50kA
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V50kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Additional equipment possibleYes
Ambient temperature during operating-25 - 60°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS862001R1597 | S802S-UCK63

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Current limiting class

3

Connectable conductor cross section solid-core

0 .. 50mm²

Over voltage category

3

Rated current

63A

Connectable conductor cross section multi-wired

0 .. 70mm²

Pollution degree

2

Voltage type

AC/DC

Number of protected poles

2

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Built-in depth

82.5mm

Frequency

50 .. 60Hz

Rated voltage

500V

Rated insulation voltage Ui

1000V

Concurrently switching neutral conductor

Suitable for flush-mounted installation

Release characteristic

K

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

50kA

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

50kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Additional equipment possible

Ambient temperature during operating

-25 .. 60°C

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.