  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Pollution degree2
Frequency0 - 50Hz
Built-in depth88.5mm
Degree of protection (IP)IP20
Current limiting class3
Suitable for flush-mounted installationNo
Rated insulation voltage Ui690V
Connectable conductor cross section multi-wired0 - 70mm²
Width in number of modular spacings3
Over voltage category3
Connectable conductor cross section solid-core0 - 50mm²
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Ambient temperature during operating-25 - 60°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Rated impulse withstand voltage Uimp8kV
Voltage typeAC
Rated current13A
Rated voltage400V
Release characteristicB
Number of protected poles3
Number of poles (total)3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS863001R0135 | S803S-B13

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Pollution degree

2

Frequency

0 .. 50Hz

Built-in depth

88.5mm

Degree of protection (IP)

IP20

Current limiting class

3

Suitable for flush-mounted installation

Rated insulation voltage Ui

690V

Connectable conductor cross section multi-wired

0 .. 70mm²

Width in number of modular spacings

3

Over voltage category

3

Connectable conductor cross section solid-core

0 .. 50mm²

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Ambient temperature during operating

-25 .. 60°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Rated impulse withstand voltage Uimp

8kV

Voltage type

AC

Rated current

13A

Rated voltage

400V

Release characteristic

B

Number of protected poles

3

Number of poles (total)

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA