Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC/DC
Rated current13A
Pollution degree2
Frequency0 - 50Hz
Built-in depth88.5mm
Degree of protection (IP)IP20
Current limiting class3
Number of protected poles3
Suitable for flush-mounted installationNo
Rated insulation voltage Ui690V
Connectable conductor cross section multi-wired0 - 70mm²
Width in number of modular spacings3
Over voltage category3
Rated voltage690V
Connectable conductor cross section solid-core0 - 50mm²
Concurrently switching neutral conductorNo
Number of poles (total)3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Ambient temperature during operating-25 - 60°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Rated impulse withstand voltage Uimp8kV
Release characteristicB
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS863001R0135 | S803S-B13

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC/DC

Rated current

13A

Pollution degree

2

Frequency

0 .. 50Hz

Built-in depth

88.5mm

Degree of protection (IP)

IP20

Current limiting class

3

Number of protected poles

3

Suitable for flush-mounted installation

Rated insulation voltage Ui

690V

Connectable conductor cross section multi-wired

0 .. 70mm²

Width in number of modular spacings

3

Over voltage category

3

Rated voltage

690V

Connectable conductor cross section solid-core

0 .. 50mm²

Concurrently switching neutral conductor

Number of poles (total)

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Ambient temperature during operating

-25 .. 60°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Rated impulse withstand voltage Uimp

8kV

Release characteristic

B

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.