  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth88.5mm
Rated current32A
Voltage typeAC/DC
Frequency0 - 50Hz
Pollution degree2
Rated insulation voltage Ui690V
Current limiting class3
Rated voltage690V
Over voltage category3
Release characteristicD
Degree of protection (IP)IP20
Width in number of modular spacings3
Connectable conductor cross section multi-wired0 - 70mm²
Number of protected poles3
Concurrently switching neutral conductorNo
Number of poles (total)3
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section solid-core0 - 50mm²
Additional equipment possibleYes
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS863001R0321 | S803S-D32

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

88.5mm

Rated current

32A

Voltage type

AC/DC

Frequency

0 .. 50Hz

Pollution degree

2

Rated insulation voltage Ui

690V

Current limiting class

3

Rated voltage

690V

Over voltage category

3

Release characteristic

D

Degree of protection (IP)

IP20

Width in number of modular spacings

3

Connectable conductor cross section multi-wired

0 .. 70mm²

Number of protected poles

3

Concurrently switching neutral conductor

Number of poles (total)

3

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section solid-core

0 .. 50mm²

Additional equipment possible

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA