Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC/DC
Built-in depth88.5mm
Current limiting class3
Release characteristicD
Over voltage category3
Rated current50A
Rated voltage690V
Rated insulation voltage Ui690V
Frequency0 - 60Hz
Width in number of modular spacings3
Number of protected poles3
Connectable conductor cross section solid-core0 - 50mm²
Degree of protection (IP)IP20
Pollution degree2
Suitable for flush-mounted installationNo
Ambient temperature during operating-25 - 60°C
Number of poles (total)3
Connectable conductor cross section multi-wired0 - 70mm²
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Concurrently switching neutral conductorNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS863001R0501 | S803S-D50

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC/DC

Built-in depth

88.5mm

Current limiting class

3

Release characteristic

D

Over voltage category

3

Rated current

50A

Rated voltage

690V

Rated insulation voltage Ui

690V

Frequency

0 .. 60Hz

Width in number of modular spacings

3

Number of protected poles

3

Connectable conductor cross section solid-core

0 .. 50mm²

Degree of protection (IP)

IP20

Pollution degree

2

Suitable for flush-mounted installation

Ambient temperature during operating

-25 .. 60°C

Number of poles (total)

3

Connectable conductor cross section multi-wired

0 .. 70mm²

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Concurrently switching neutral conductor

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.