Technical specifications

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated insulation voltage Ui690V
Rated impulse withstand voltage Uimp8kV
Rated current40A
Number of poles (total)3
Release characteristicKM
Rated voltage690V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Current limiting class3
Pollution degree2
Voltage typeAC/DC
Over voltage category3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Concurrently switching neutral conductorNo
Frequency0 - 60Hz
Built-in depth88.5mm
Degree of protection (IP)IP20
Additional equipment possibleYes
Connectable conductor cross section multi-wired0 - 70mm²
Connectable conductor cross section solid-core0 - 50mm²
Width in number of modular spacings3
Ambient temperature during operating-25 - 60°C
Number of protected poles3
Suitable for flush-mounted installationNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS863001R0556 | S803S-KM40

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated insulation voltage Ui

690V

Rated impulse withstand voltage Uimp

8kV

Rated current

40A

Number of poles (total)

3

Release characteristic

KM

Rated voltage

690V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Current limiting class

3

Pollution degree

2

Voltage type

AC/DC

Over voltage category

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Concurrently switching neutral conductor

Frequency

0 .. 60Hz

Built-in depth

88.5mm

Degree of protection (IP)

IP20

Additional equipment possible

Connectable conductor cross section multi-wired

0 .. 70mm²

Connectable conductor cross section solid-core

0 .. 50mm²

Width in number of modular spacings

3

Ambient temperature during operating

-25 .. 60°C

Number of protected poles

3

Suitable for flush-mounted installation

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.