Technical specifications

Release characteristicK
Rated insulation voltage Ui690V
Rated voltage690V
Number of poles (total)3
Rated current40A
Number of protected poles3
Rated impulse withstand voltage Uimp8kV
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Current limiting class3
Pollution degree2
Frequency0 - 60Hz
Additional equipment possibleYes
Concurrently switching neutral conductorNo
Width in number of modular spacings3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Connectable conductor cross section multi-wired0 - 70mm²
Built-in depth88.5mm
Connectable conductor cross section solid-core0 - 50mm²
Ambient temperature during operating-25 - 60°C
Voltage typeAC/DC
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Over voltage category3
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS863001R0557 | S803S-K40

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

K

Rated insulation voltage Ui

690V

Rated voltage

690V

Number of poles (total)

3

Rated current

40A

Number of protected poles

3

Rated impulse withstand voltage Uimp

8kV

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Current limiting class

3

Pollution degree

2

Frequency

0 .. 60Hz

Additional equipment possible

Concurrently switching neutral conductor

Width in number of modular spacings

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Connectable conductor cross section multi-wired

0 .. 70mm²

Built-in depth

88.5mm

Connectable conductor cross section solid-core

0 .. 50mm²

Ambient temperature during operating

-25 .. 60°C

Voltage type

AC/DC

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Over voltage category

3

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.