Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth88.5mm
Voltage typeAC/DC
Over voltage category3
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 60°C
Current limiting class3
Frequency0 - 60Hz
Connectable conductor cross section multi-wired0 - 70mm²
Connectable conductor cross section solid-core0 - 50mm²
Concurrently switching neutral conductorNo
Pollution degree2
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Width in number of modular spacings3
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Release characteristicK
Number of protected poles3
Number of poles (total)3
Rated current63A
Rated impulse withstand voltage Uimp8kV
Rated insulation voltage Ui690V
Rated voltage400V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS863001R0597 | S803S-K63

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

88.5mm

Voltage type

AC/DC

Over voltage category

3

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 60°C

Current limiting class

3

Frequency

0 .. 60Hz

Connectable conductor cross section multi-wired

0 .. 70mm²

Connectable conductor cross section solid-core

0 .. 50mm²

Concurrently switching neutral conductor

Pollution degree

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Width in number of modular spacings

3

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Release characteristic

K

Number of protected poles

3

Number of poles (total)

3

Rated current

63A

Rated impulse withstand voltage Uimp

8kV

Rated insulation voltage Ui

690V

Rated voltage

400V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA