Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristicD
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Number of protected poles4
Number of poles (total)4
Rated current6A
Rated voltage690V
Rated insulation voltage Ui690V
Rated impulse withstand voltage Uimp8kV
Voltage typeAC
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Concurrently switching neutral conductorNo
Pollution degree3
Current limiting class3
Suitable for flush-mounted installationNo
Over voltage category3
Additional equipment possibleYes
Width in number of modular spacings4
Built-in depth82.5mm
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section multi-wired0 - 70mm²
Connectable conductor cross section solid-core0 - 50mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS864001R0061 | S804S-D6

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

D

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Number of protected poles

4

Number of poles (total)

4

Rated current

6A

Rated voltage

690V

Rated insulation voltage Ui

690V

Rated impulse withstand voltage Uimp

8kV

Voltage type

AC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Concurrently switching neutral conductor

Pollution degree

3

Current limiting class

3

Suitable for flush-mounted installation

Over voltage category

3

Additional equipment possible

Width in number of modular spacings

4

Built-in depth

82.5mm

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section multi-wired

0 .. 70mm²

Connectable conductor cross section solid-core

0 .. 50mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.