Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Connectable conductor cross section multi-wired0 - 70mm²
Built-in depth82.5mm
Degree of protection (IP)IP20
Width in number of modular spacings4
Suitable for flush-mounted installationNo
Frequency50 - 60Hz
Over voltage category3
Ambient temperature during operating-25 - 60°C
Current limiting class3
Pollution degree3
Additional equipment possibleYes
Rated insulation voltage Ui690V
Connectable conductor cross section solid-core0 - 50mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Rated impulse withstand voltage Uimp8kV
Voltage typeAC
Rated current16A
Rated voltage400V
Release characteristicB
Number of protected poles4
Number of poles (total)4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS864001R0165 | S804S-B16

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Connectable conductor cross section multi-wired

0 .. 70mm²

Built-in depth

82.5mm

Degree of protection (IP)

IP20

Width in number of modular spacings

4

Suitable for flush-mounted installation

Frequency

50 .. 60Hz

Over voltage category

3

Ambient temperature during operating

-25 .. 60°C

Current limiting class

3

Pollution degree

3

Additional equipment possible

Rated insulation voltage Ui

690V

Connectable conductor cross section solid-core

0 .. 50mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Rated impulse withstand voltage Uimp

8kV

Voltage type

AC

Rated current

16A

Rated voltage

400V

Release characteristic

B

Number of protected poles

4

Number of poles (total)

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA