Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Over voltage category3
Rated insulation voltage Ui690V
Degree of protection (IP)IP20
Release characteristicC
Pollution degree3
Frequency50 - 60Hz
Width in number of modular spacings4
Voltage typeAC
Rated voltage690V
Current limiting class3
Built-in depth82.5mm
Rated current63A
Concurrently switching neutral conductorNo
Suitable for flush-mounted installationNo
Number of protected poles4
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Connectable conductor cross section multi-wired0 - 70mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Additional equipment possibleYes
Number of poles (total)4
Rated impulse withstand voltage Uimp8kV
Ambient temperature during operating-25 - 60°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Connectable conductor cross section solid-core0 - 50mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS864001R0634 | S804S-C63

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Over voltage category

3

Rated insulation voltage Ui

690V

Degree of protection (IP)

IP20

Release characteristic

C

Pollution degree

3

Frequency

50 .. 60Hz

Width in number of modular spacings

4

Voltage type

AC

Rated voltage

690V

Current limiting class

3

Built-in depth

82.5mm

Rated current

63A

Concurrently switching neutral conductor

Suitable for flush-mounted installation

Number of protected poles

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Connectable conductor cross section multi-wired

0 .. 70mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Additional equipment possible

Number of poles (total)

4

Rated impulse withstand voltage Uimp

8kV

Ambient temperature during operating

-25 .. 60°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Connectable conductor cross section solid-core

0 .. 50mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.