Technical specifications

Rated current10A
Built-in depth82.5mm
Frequency0 - 0Hz
Voltage typeDC
Rated voltage750V
Release characteristicK
Width in number of modular spacings4
Current limiting class3
Concurrently switching neutral conductorNo
Rated insulation voltage Ui1000V
Pollution degree2
Degree of protection (IP)IP20
Over voltage category3
Number of protected poles4
Connectable conductor cross section solid-core0 - 50mm²
Connectable conductor cross section multi-wired0 - 70mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Suitable for flush-mounted installationNo
Additional equipment possibleYes
Ambient temperature during operating-25 - 60°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V50kA
Number of poles (total)4
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V50kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS864001R1427 | S804S-UCK10

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

10A

Built-in depth

82.5mm

Frequency

0 .. 0Hz

Voltage type

DC

Rated voltage

750V

Release characteristic

K

Width in number of modular spacings

4

Current limiting class

3

Concurrently switching neutral conductor

Rated insulation voltage Ui

1000V

Pollution degree

2

Degree of protection (IP)

IP20

Over voltage category

3

Number of protected poles

4

Connectable conductor cross section solid-core

0 .. 50mm²

Connectable conductor cross section multi-wired

0 .. 70mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Suitable for flush-mounted installation

Additional equipment possible

Ambient temperature during operating

-25 .. 60°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

50kA

Number of poles (total)

4

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

50kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.