Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)4
Rated current20A
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V50kA
Release characteristicK
Rated voltage750V
Frequency0 - 0Hz
Rated insulation voltage Ui1000V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Voltage typeDC
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V50kA
Concurrently switching neutral conductorNo
Number of protected poles4
Built-in depth82.5mm
Degree of protection (IP)IP20
Additional equipment possibleYes
Rated impulse withstand voltage Uimp8kV
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section multi-wired0 - 70mm²
Pollution degree2
Connectable conductor cross section solid-core0 - 50mm²
Over voltage category3
Width in number of modular spacings4
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS864001R1487 | S804S-UCK20

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

4

Rated current

20A

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

50kA

Release characteristic

K

Rated voltage

750V

Frequency

0 .. 0Hz

Rated insulation voltage Ui

1000V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Voltage type

DC

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

50kA

Concurrently switching neutral conductor

Number of protected poles

4

Built-in depth

82.5mm

Degree of protection (IP)

IP20

Additional equipment possible

Rated impulse withstand voltage Uimp

8kV

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section multi-wired

0 .. 70mm²

Pollution degree

2

Connectable conductor cross section solid-core

0 .. 50mm²

Over voltage category

3

Width in number of modular spacings

4

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.