Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristicK
Rated voltage750V
Rated current32A
Rated insulation voltage Ui1000V
Number of poles (total)4
Number of protected poles4
Rated impulse withstand voltage Uimp8kV
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Concurrently switching neutral conductorNo
Voltage typeDC
Pollution degree2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V50kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V50kA
Suitable for flush-mounted installationNo
Width in number of modular spacings4
Ambient temperature during operating-25 - 60°C
Built-in depth82.5mm
Degree of protection (IP)IP20
Connectable conductor cross section solid-core0 - 50mm²
Over voltage category3
Frequency0 - 0Hz
Connectable conductor cross section multi-wired0 - 70mm²
Additional equipment possibleYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS864001R1537 | S804S-UCK32

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

K

Rated voltage

750V

Rated current

32A

Rated insulation voltage Ui

1000V

Number of poles (total)

4

Number of protected poles

4

Rated impulse withstand voltage Uimp

8kV

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Concurrently switching neutral conductor

Voltage type

DC

Pollution degree

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

50kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

50kA

Suitable for flush-mounted installation

Width in number of modular spacings

4

Ambient temperature during operating

-25 .. 60°C

Built-in depth

82.5mm

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

0 .. 50mm²

Over voltage category

3

Frequency

0 .. 0Hz

Connectable conductor cross section multi-wired

0 .. 70mm²

Additional equipment possible

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.