Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth82.5mm
Rated current32A
Rated voltage750V
Voltage typeDC
Rated insulation voltage Ui1000V
Connectable conductor cross section solid-core0 - 50mm²
Concurrently switching neutral conductorNo
Frequency0 - 0Hz
Width in number of modular spacings4
Number of poles (total)4
Additional equipment possibleYes
Connectable conductor cross section multi-wired0 - 70mm²
Degree of protection (IP)IP20
Suitable for flush-mounted installationNo
Pollution degree2
Ambient temperature during operating-25 - 60°C
Current limiting class3
Number of protected poles4
Release characteristicK
Over voltage category3
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V50kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V50kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS864001R1537 | S804S-UCK32

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

82.5mm

Rated current

32A

Rated voltage

750V

Voltage type

DC

Rated insulation voltage Ui

1000V

Connectable conductor cross section solid-core

0 .. 50mm²

Concurrently switching neutral conductor

Frequency

0 .. 0Hz

Width in number of modular spacings

4

Number of poles (total)

4

Additional equipment possible

Connectable conductor cross section multi-wired

0 .. 70mm²

Degree of protection (IP)

IP20

Suitable for flush-mounted installation

Pollution degree

2

Ambient temperature during operating

-25 .. 60°C

Current limiting class

3

Number of protected poles

4

Release characteristic

K

Over voltage category

3

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

50kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

50kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.