Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Suitable for flush-mounted installationNo
Rated voltage750V
Current limiting class3
Built-in depth82.5mm
Degree of protection (IP)IP20
Concurrently switching neutral conductorNo
Ambient temperature during operating-25 - 60°C
Number of protected poles4
Frequency0 - 0Hz
Width in number of modular spacings4
Connectable conductor cross section solid-core0 - 50mm²
Rated current50A
Voltage typeDC
Over voltage category3
Rated insulation voltage Ui1000V
Connectable conductor cross section multi-wired0 - 70mm²
Release characteristicK
Pollution degree2
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Number of poles (total)4
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V50kA
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V50kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS864001R1577 | S804S-UCK50

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Suitable for flush-mounted installation

Rated voltage

750V

Current limiting class

3

Built-in depth

82.5mm

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Ambient temperature during operating

-25 .. 60°C

Number of protected poles

4

Frequency

0 .. 0Hz

Width in number of modular spacings

4

Connectable conductor cross section solid-core

0 .. 50mm²

Rated current

50A

Voltage type

DC

Over voltage category

3

Rated insulation voltage Ui

1000V

Connectable conductor cross section multi-wired

0 .. 70mm²

Release characteristic

K

Pollution degree

2

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Number of poles (total)

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

50kA

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

50kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.