Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC
Degree of protection (IP)IP20
Rated current63A
Current limiting class3
Explosion-proofNo
Pollution degree3
Power loss12.8W
Release characteristicK
Width in number of modular spacings2
Over voltage category4
Rated voltage440V
Built-in depth82.5mm
Rated insulation voltage Ui500V
Frequency50 - 60Hz
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Rated impulse withstand voltage Uimp8kV
Flush-mounted installationNo
Number of protected poles2
Connectable conductor cross section multi-wired0 - 70mm²
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Suitable for flush-mounted installationNo
Ambient temperature during operating-25 - 60°C
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Connectable conductor cross section solid-core0 - 50mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS882001R0597 | S802C-K63

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC

Degree of protection (IP)

IP20

Rated current

63A

Current limiting class

3

Explosion-proof

Pollution degree

3

Power loss

12.8W

Release characteristic

K

Width in number of modular spacings

2

Over voltage category

4

Rated voltage

440V

Built-in depth

82.5mm

Rated insulation voltage Ui

500V

Frequency

50 .. 60Hz

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Rated impulse withstand voltage Uimp

8kV

Flush-mounted installation

Number of protected poles

2

Connectable conductor cross section multi-wired

0 .. 70mm²

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Suitable for flush-mounted installation

Ambient temperature during operating

-25 .. 60°C

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Connectable conductor cross section solid-core

0 .. 50mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.