Technical specifications

Voltage typeAC
Width in number of modular spacings3
Rated insulation voltage Ui500V
Current limiting class3
Over voltage category4
Rated voltage440V
Built-in depth82.5mm
Degree of protection (IP)IP20
Frequency50 - 60Hz
Release characteristicD
Pollution degree3
Rated current40A
Power loss11.1W
Explosion-proofNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Concurrently switching neutral conductorNo
Flush-mounted installationNo
Number of poles (total)3
Ambient temperature during operating-25 - 60°C
Additional equipment possibleYes
Connectable conductor cross section solid-core0 - 50mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Connectable conductor cross section multi-wired0 - 70mm²
Number of protected poles3
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated impulse withstand voltage Uimp8kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS883001R0401 | S803C-D40

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC

Width in number of modular spacings

3

Rated insulation voltage Ui

500V

Current limiting class

3

Over voltage category

4

Rated voltage

440V

Built-in depth

82.5mm

Degree of protection (IP)

IP20

Frequency

50 .. 60Hz

Release characteristic

D

Pollution degree

3

Rated current

40A

Power loss

11.1W

Explosion-proof

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Concurrently switching neutral conductor

Flush-mounted installation

Number of poles (total)

3

Ambient temperature during operating

-25 .. 60°C

Additional equipment possible

Connectable conductor cross section solid-core

0 .. 50mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Connectable conductor cross section multi-wired

0 .. 70mm²

Number of protected poles

3

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated impulse withstand voltage Uimp

8kV