  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage440V
Built-in depth82.5mm
Rated current10A
Voltage typeAC/DC
Frequency50 - 60Hz
Rated insulation voltage Ui500V
Release characteristicC
Pollution degree3
Over voltage category4
Degree of protection (IP)IP20
Width in number of modular spacings4
Current limiting class3
Power loss6W
Connectable conductor cross section multi-wired0 - 70mm²
Connectable conductor cross section solid-core0 - 50mm²
Explosion-proofNo
Flush-mounted installationNo
Concurrently switching neutral conductorNo
Additional equipment possibleYes
Number of protected poles4
Suitable for flush-mounted installationNo
Ambient temperature during operating-25 - 60°C
Number of poles (total)4
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS884001R0104 | S804C-C10

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

440V

Built-in depth

82.5mm

Rated current

10A

Voltage type

AC/DC

Frequency

50 .. 60Hz

Rated insulation voltage Ui

500V

Release characteristic

C

Pollution degree

3

Over voltage category

4

Degree of protection (IP)

IP20

Width in number of modular spacings

4

Current limiting class

3

Power loss

6W

Connectable conductor cross section multi-wired

0 .. 70mm²

Connectable conductor cross section solid-core

0 .. 50mm²

Explosion-proof

Flush-mounted installation

Concurrently switching neutral conductor

Additional equipment possible

Number of protected poles

4

Suitable for flush-mounted installation

Ambient temperature during operating

-25 .. 60°C

Number of poles (total)

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.