Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth82.5mm
Rated voltage440V
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Width in number of modular spacings4
Degree of protection (IP)IP20
Power loss12.8W
Suitable for flush-mounted installationNo
Connectable conductor cross section solid-core0 - 50mm²
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Flush-mounted installationNo
Over voltage category4
Current limiting class3
Ambient temperature during operating-25 - 60°C
Rated insulation voltage Ui500V
Connectable conductor cross section multi-wired0 - 70mm²
Explosion-proofNo
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Rated impulse withstand voltage Uimp8kV
Pollution degree3
Number of poles (total)4
Number of protected poles4
Release characteristicC
Rated current32A
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Voltage typeAC/DC
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS884001R0324 | S804C-C32

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

82.5mm

Rated voltage

440V

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Width in number of modular spacings

4

Degree of protection (IP)

IP20

Power loss

12.8W

Suitable for flush-mounted installation

Connectable conductor cross section solid-core

0 .. 50mm²

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Flush-mounted installation

Over voltage category

4

Current limiting class

3

Ambient temperature during operating

-25 .. 60°C

Rated insulation voltage Ui

500V

Connectable conductor cross section multi-wired

0 .. 70mm²

Explosion-proof

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Rated impulse withstand voltage Uimp

8kV

Pollution degree

3

Number of poles (total)

4

Number of protected poles

4

Release characteristic

C

Rated current

32A

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Voltage type

AC/DC

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.