Technical specifications

Release characteristic

B

Rated impulse withstand voltage Uimp

8kV

Rated voltage

690V

Rated current

10A

Rated insulation voltage Ui

690V

Number of protected poles

1

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

36kA

Voltage type

AC/DC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

36kA

Number of poles (total)

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Current limiting class

3

Concurrently switching neutral conductor

No

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Frequency

50 - 60Hz

Additional equipment possible

Yes

Suitable for flush-mounted installation

No

Degree of protection (IP)

IP20

Pollution degree

3

Over voltage category

4

Width in number of modular spacings

1

Connectable conductor cross section multi-wired

0 - 70mm²

Ambient temperature during operating

-25 - 60°C

Connectable conductor cross section solid-core

0 - 50mm²

Built-in depth

82.5mm

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CCS891001R0105 | S801N-B10

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

B

Rated impulse withstand voltage Uimp

8kV

Rated voltage

690V

Rated current

10A

Rated insulation voltage Ui

690V

Number of protected poles

1

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

36kA

Voltage type

AC/DC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

36kA

Number of poles (total)

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Current limiting class

3

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Frequency

50 .. 60Hz

Additional equipment possible

Suitable for flush-mounted installation

Degree of protection (IP)

IP20

Pollution degree

3

Over voltage category

4

Width in number of modular spacings

1

Connectable conductor cross section multi-wired

0 .. 70mm²

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section solid-core

0 .. 50mm²

Built-in depth

82.5mm