Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage690V
Rated current13A
Built-in depth82.5mm
Release characteristicD
Frequency50 - 60Hz
Voltage typeAC/DC
Over voltage category4
Number of protected poles1
Pollution degree3
Concurrently switching neutral conductorNo
Connectable conductor cross section multi-wired0 - 70mm²
Number of poles (total)1
Width in number of modular spacings1
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V36kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Rated insulation voltage Ui690V
Connectable conductor cross section solid-core0 - 50mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V36kA
Rated impulse withstand voltage Uimp8kV
Suitable for flush-mounted installationNo
Current limiting class3
Ambient temperature during operating-25 - 60°C
Additional equipment possibleYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS891001R0131 | S801N-D13

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

690V

Rated current

13A

Built-in depth

82.5mm

Release characteristic

D

Frequency

50 .. 60Hz

Voltage type

AC/DC

Over voltage category

4

Number of protected poles

1

Pollution degree

3

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

0 .. 70mm²

Number of poles (total)

1

Width in number of modular spacings

1

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

36kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Rated insulation voltage Ui

690V

Connectable conductor cross section solid-core

0 .. 50mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

36kA

Rated impulse withstand voltage Uimp

8kV

Suitable for flush-mounted installation

Current limiting class

3

Ambient temperature during operating

-25 .. 60°C

Additional equipment possible

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.