  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current13A
Voltage typeAC/DC
Built-in depth82.5mm
Rated insulation voltage Ui690V
Frequency50 - 60Hz
Release characteristicC
Rated voltage690V
Pollution degree3
Over voltage category4
Width in number of modular spacings1
Current limiting class3
Additional equipment possibleYes
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V36kA
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V36kA
Ambient temperature during operating-25 - 60°C
Suitable for flush-mounted installationNo
Number of protected poles1
Connectable conductor cross section solid-core0 - 50mm²
Connectable conductor cross section multi-wired0 - 70mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V20kA
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V36kA
Number of poles (total)1
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS891001R0134 | S801N-C13

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

13A

Voltage type

AC/DC

Built-in depth

82.5mm

Rated insulation voltage Ui

690V

Frequency

50 .. 60Hz

Release characteristic

C

Rated voltage

690V

Pollution degree

3

Over voltage category

4

Width in number of modular spacings

1

Current limiting class

3

Additional equipment possible

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

36kA

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

36kA

Ambient temperature during operating

-25 .. 60°C

Suitable for flush-mounted installation

Number of protected poles

1

Connectable conductor cross section solid-core

0 .. 50mm²

Connectable conductor cross section multi-wired

0 .. 70mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

20kA

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

36kA

Number of poles (total)

1

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.