Technical specifications

Rated voltage690V
Number of poles (total)1
Rated current63A
Rated impulse withstand voltage Uimp8kV
Rated insulation voltage Ui690V
Release characteristicB
Frequency50 - 60Hz
Over voltage category4
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Additional equipment possibleYes
Width in number of modular spacings1
Pollution degree3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V36kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V36kA
Suitable for flush-mounted installationNo
Current limiting class3
Built-in depth82.5mm
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V20kA
Concurrently switching neutral conductorNo
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section solid-core0 - 50mm²
Number of protected poles1
Connectable conductor cross section multi-wired0 - 70mm²
Voltage typeAC/DC
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS891001R0635 | S801N-B63

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

690V

Number of poles (total)

1

Rated current

63A

Rated impulse withstand voltage Uimp

8kV

Rated insulation voltage Ui

690V

Release characteristic

B

Frequency

50 .. 60Hz

Over voltage category

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Additional equipment possible

Width in number of modular spacings

1

Pollution degree

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

36kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

36kA

Suitable for flush-mounted installation

Current limiting class

3

Built-in depth

82.5mm

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

20kA

Concurrently switching neutral conductor

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section solid-core

0 .. 50mm²

Number of protected poles

1

Connectable conductor cross section multi-wired

0 .. 70mm²

Voltage type

AC/DC