Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles2
Number of poles (total)2
Release characteristicB
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V20kA
Rated insulation voltage Ui690V
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V20kA
Suitable for flush-mounted installationNo
Over voltage category4
Pollution degree3
Current limiting class3
Concurrently switching neutral conductorNo
Additional equipment possibleYes
Rated current6A
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V36kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V36kA
Voltage typeAC/DC
Width in number of modular spacings2
Degree of protection (IP)IP20
Rated voltage400V
Connectable conductor cross section multi-wired0 - 70mm²
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section solid-core0 - 50mm²
Built-in depth82.5mm
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS892001R0065 | S802N-B6

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles

2

Number of poles (total)

2

Release characteristic

B

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

20kA

Rated insulation voltage Ui

690V

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

20kA

Suitable for flush-mounted installation

Over voltage category

4

Pollution degree

3

Current limiting class

3

Concurrently switching neutral conductor

Additional equipment possible

Rated current

6A

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

36kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

36kA

Voltage type

AC/DC

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Rated voltage

400V

Connectable conductor cross section multi-wired

0 .. 70mm²

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section solid-core

0 .. 50mm²

Built-in depth

82.5mm

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.