Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth82.5mm
Rated current25A
Release characteristicC
Over voltage category4
Rated insulation voltage Ui690V
Rated voltage400V
Frequency50 - 60Hz
Current limiting class3
Voltage typeAC/DC
Additional equipment possibleYes
Number of protected poles2
Number of poles (total)2
Degree of protection (IP)IP20
Concurrently switching neutral conductorNo
Connectable conductor cross section multi-wired0 - 70mm²
Width in number of modular spacings2
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Pollution degree3
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section solid-core0 - 50mm²
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V36kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V36kA
Suitable for flush-mounted installationNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS892001R0254 | S802N-C25

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

82.5mm

Rated current

25A

Release characteristic

C

Over voltage category

4

Rated insulation voltage Ui

690V

Rated voltage

400V

Frequency

50 .. 60Hz

Current limiting class

3

Voltage type

AC/DC

Additional equipment possible

Number of protected poles

2

Number of poles (total)

2

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

0 .. 70mm²

Width in number of modular spacings

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Pollution degree

3

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section solid-core

0 .. 50mm²

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

36kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

36kA

Suitable for flush-mounted installation

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.