Technical specifications

Frequency50 - 60Hz
Over voltage category4
Voltage typeAC/DC
Rated voltage400V
Built-in depth82.5mm
Width in number of modular spacings2
Rated insulation voltage Ui690V
Release characteristicD
Pollution degree3
Current limiting class3
Rated current40A
Degree of protection (IP)IP20
Concurrently switching neutral conductorNo
Connectable conductor cross section solid-core0 - 50mm²
Suitable for flush-mounted installationNo
Number of protected poles2
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section multi-wired0 - 70mm²
Number of poles (total)2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V36kA
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V36kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS892001R0401 | S802N-D40

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Frequency

50 .. 60Hz

Over voltage category

4

Voltage type

AC/DC

Rated voltage

400V

Built-in depth

82.5mm

Width in number of modular spacings

2

Rated insulation voltage Ui

690V

Release characteristic

D

Pollution degree

3

Current limiting class

3

Rated current

40A

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

0 .. 50mm²

Suitable for flush-mounted installation

Number of protected poles

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section multi-wired

0 .. 70mm²

Number of poles (total)

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

36kA

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

36kA