Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth82.5mm
Rated voltage690V
Voltage typeAC/DC
Rated current16A
Pollution degree3
Over voltage category4
Number of protected poles3
Concurrently switching neutral conductorNo
Degree of protection (IP)IP20
Rated impulse withstand voltage Uimp8kV
Number of poles (total)3
Release characteristicD
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V36kA
Rated insulation voltage Ui690V
Connectable conductor cross section multi-wired0 - 70mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Width in number of modular spacings3
Current limiting class3
Additional equipment possibleYes
Ambient temperature during operating-25 - 60°C
Frequency50 - 60Hz
Connectable conductor cross section solid-core0 - 50mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V36kA
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS893001R0161 | S803N-D16

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

82.5mm

Rated voltage

690V

Voltage type

AC/DC

Rated current

16A

Pollution degree

3

Over voltage category

4

Number of protected poles

3

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Rated impulse withstand voltage Uimp

8kV

Number of poles (total)

3

Release characteristic

D

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

36kA

Rated insulation voltage Ui

690V

Connectable conductor cross section multi-wired

0 .. 70mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Width in number of modular spacings

3

Current limiting class

3

Additional equipment possible

Ambient temperature during operating

-25 .. 60°C

Frequency

50 .. 60Hz

Connectable conductor cross section solid-core

0 .. 50mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

36kA

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA