Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current40A
Release characteristicD
Rated insulation voltage Ui690V
Built-in depth82.5mm
Rated voltage690V
Frequency50 - 60Hz
Voltage typeAC/DC
Number of protected poles3
Width in number of modular spacings3
Over voltage category4
Pollution degree3
Current limiting class3
Degree of protection (IP)IP20
Additional equipment possibleYes
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Ambient temperature during operating-25 - 60°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Rated impulse withstand voltage Uimp8kV
Connectable conductor cross section multi-wired0 - 70mm²
Concurrently switching neutral conductorNo
Number of poles (total)3
Connectable conductor cross section solid-core0 - 50mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V36kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V36kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS893001R0401 | S803N-D40

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

40A

Release characteristic

D

Rated insulation voltage Ui

690V

Built-in depth

82.5mm

Rated voltage

690V

Frequency

50 .. 60Hz

Voltage type

AC/DC

Number of protected poles

3

Width in number of modular spacings

3

Over voltage category

4

Pollution degree

3

Current limiting class

3

Degree of protection (IP)

IP20

Additional equipment possible

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Ambient temperature during operating

-25 .. 60°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Rated impulse withstand voltage Uimp

8kV

Connectable conductor cross section multi-wired

0 .. 70mm²

Concurrently switching neutral conductor

Number of poles (total)

3

Connectable conductor cross section solid-core

0 .. 50mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

36kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

36kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.