Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth82.5mm
Voltage typeAC/DC
Rated current40A
Release characteristicC
Frequency50 - 60Hz
Rated voltage690V
Rated insulation voltage Ui690V
Pollution degree3
Number of protected poles3
Degree of protection (IP)IP20
Current limiting class3
Over voltage category4
Width in number of modular spacings3
Additional equipment possibleYes
Number of poles (total)3
Connectable conductor cross section multi-wired0 - 70mm²
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section solid-core0 - 50mm²
Suitable for flush-mounted installationNo
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V36kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V36kA
Rated impulse withstand voltage Uimp8kV

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS893001R0404 | S803N-C40

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

82.5mm

Voltage type

AC/DC

Rated current

40A

Release characteristic

C

Frequency

50 .. 60Hz

Rated voltage

690V

Rated insulation voltage Ui

690V

Pollution degree

3

Number of protected poles

3

Degree of protection (IP)

IP20

Current limiting class

3

Over voltage category

4

Width in number of modular spacings

3

Additional equipment possible

Number of poles (total)

3

Connectable conductor cross section multi-wired

0 .. 70mm²

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section solid-core

0 .. 50mm²

Suitable for flush-mounted installation

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

36kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

36kA

Rated impulse withstand voltage Uimp

8kV

From same serie