Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Number of protected poles3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V36kA
Rated current63A
Number of poles (total)3
Rated insulation voltage Ui690V
Release characteristicB
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Rated voltage690V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V36kA
Rated impulse withstand voltage Uimp8kV
Built-in depth82.5mm
Current limiting class3
Suitable for flush-mounted installationNo
Concurrently switching neutral conductorNo
Voltage typeAC/DC
Additional equipment possibleYes
Connectable conductor cross section multi-wired0 - 70mm²
Width in number of modular spacings3
Pollution degree3
Ambient temperature during operating-25 - 60°C
Over voltage category4
Degree of protection (IP)IP20
Frequency50 - 60Hz
Connectable conductor cross section solid-core0 - 50mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS893001R0635 | S803N-B63

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Number of protected poles

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

36kA

Rated current

63A

Number of poles (total)

3

Rated insulation voltage Ui

690V

Release characteristic

B

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated voltage

690V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

36kA

Rated impulse withstand voltage Uimp

8kV

Built-in depth

82.5mm

Current limiting class

3

Suitable for flush-mounted installation

Concurrently switching neutral conductor

Voltage type

AC/DC

Additional equipment possible

Connectable conductor cross section multi-wired

0 .. 70mm²

Width in number of modular spacings

3

Pollution degree

3

Ambient temperature during operating

-25 .. 60°C

Over voltage category

4

Degree of protection (IP)

IP20

Frequency

50 .. 60Hz

Connectable conductor cross section solid-core

0 .. 50mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.