Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristicD
Number of poles (total)4
Rated voltage690V
Number of protected poles4
Rated insulation voltage Ui690V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V30kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V36kA
Current limiting class3
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V36kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V30kA
Frequency50 - 60Hz
Suitable for flush-mounted installationNo
Concurrently switching neutral conductorNo
Rated current6A
Width in number of modular spacings4
Pollution degree3
Over voltage category4
Additional equipment possibleYes
Connectable conductor cross section multi-wired0 - 70mm²
Connectable conductor cross section solid-core0 - 50mm²
Built-in depth82.5mm
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 60°C
Voltage typeAC/DC
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS894001R0061 | S804N-D6

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

D

Number of poles (total)

4

Rated voltage

690V

Number of protected poles

4

Rated insulation voltage Ui

690V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

30kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

36kA

Current limiting class

3

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

36kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

30kA

Frequency

50 .. 60Hz

Suitable for flush-mounted installation

Concurrently switching neutral conductor

Rated current

6A

Width in number of modular spacings

4

Pollution degree

3

Over voltage category

4

Additional equipment possible

Connectable conductor cross section multi-wired

0 .. 70mm²

Connectable conductor cross section solid-core

0 .. 50mm²

Built-in depth

82.5mm

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 60°C

Voltage type

AC/DC

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.