Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth82.5mm
Current limiting class3
Rated insulation voltage Ui690V
Frequency50 - 60Hz
Over voltage category4
Pollution degree3
Concurrently switching neutral conductorNo
Degree of protection (IP)IP20
Suitable for flush-mounted installationNo
Width in number of modular spacings4
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Connectable conductor cross section solid-core0 - 50mm²
Ambient temperature during operating-25 - 60°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V36kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Connectable conductor cross section multi-wired0 - 70mm²
Additional equipment possibleYes
Number of protected poles4
Release characteristicD
Rated current13A
Number of poles (total)4
Voltage typeAC
Rated impulse withstand voltage Uimp8kV
Rated voltage400V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V36kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS894001R0131 | S804N-D13

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

82.5mm

Current limiting class

3

Rated insulation voltage Ui

690V

Frequency

50 .. 60Hz

Over voltage category

4

Pollution degree

3

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Suitable for flush-mounted installation

Width in number of modular spacings

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Connectable conductor cross section solid-core

0 .. 50mm²

Ambient temperature during operating

-25 .. 60°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

36kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Connectable conductor cross section multi-wired

0 .. 70mm²

Additional equipment possible

Number of protected poles

4

Release characteristic

D

Rated current

13A

Number of poles (total)

4

Voltage type

AC

Rated impulse withstand voltage Uimp

8kV

Rated voltage

400V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

36kA