Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current16A
Over voltage category4
Frequency50 - 60Hz
Voltage typeAC/DC
Release characteristicB
Built-in depth82.5mm
Number of protected poles4
Current limiting class3
Rated insulation voltage Ui690V
Rated voltage690V
Width in number of modular spacings4
Pollution degree3
Degree of protection (IP)IP20
Concurrently switching neutral conductorNo
Number of poles (total)4
Connectable conductor cross section solid-core0 - 50mm²
Ambient temperature during operating-25 - 60°C
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Suitable for flush-mounted installationNo
Connectable conductor cross section multi-wired0 - 70mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V36kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V36kA
Rated impulse withstand voltage Uimp8kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS894001R0165 | S804N-B16

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

16A

Over voltage category

4

Frequency

50 .. 60Hz

Voltage type

AC/DC

Release characteristic

B

Built-in depth

82.5mm

Number of protected poles

4

Current limiting class

3

Rated insulation voltage Ui

690V

Rated voltage

690V

Width in number of modular spacings

4

Pollution degree

3

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Number of poles (total)

4

Connectable conductor cross section solid-core

0 .. 50mm²

Ambient temperature during operating

-25 .. 60°C

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Suitable for flush-mounted installation

Connectable conductor cross section multi-wired

0 .. 70mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

36kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

36kA

Rated impulse withstand voltage Uimp

8kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.