Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles4
Release characteristicD
Number of poles (total)4
Rated insulation voltage Ui690V
Rated voltage690V
Rated current20A
Voltage typeAC/DC
Rated impulse withstand voltage Uimp8kV
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V36kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V36kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Suitable for flush-mounted installationNo
Over voltage category4
Pollution degree3
Width in number of modular spacings4
Concurrently switching neutral conductorNo
Degree of protection (IP)IP20
Additional equipment possibleYes
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section solid-core0 - 50mm²
Built-in depth82.5mm
Connectable conductor cross section multi-wired0 - 70mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS894001R0201 | S804N-D20

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles

4

Release characteristic

D

Number of poles (total)

4

Rated insulation voltage Ui

690V

Rated voltage

690V

Rated current

20A

Voltage type

AC/DC

Rated impulse withstand voltage Uimp

8kV

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

36kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

36kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Suitable for flush-mounted installation

Over voltage category

4

Pollution degree

3

Width in number of modular spacings

4

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Additional equipment possible

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section solid-core

0 .. 50mm²

Built-in depth

82.5mm

Connectable conductor cross section multi-wired

0 .. 70mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.