Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage690V
Built-in depth82.5mm
Frequency50 - 60Hz
Over voltage category4
Rated current40A
Rated insulation voltage Ui690V
Current limiting class3
Concurrently switching neutral conductorNo
Width in number of modular spacings4
Release characteristicB
Number of protected poles4
Number of poles (total)4
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Pollution degree3
Voltage typeAC/DC
Connectable conductor cross section solid-core0 - 50mm²
Degree of protection (IP)IP20
Suitable for flush-mounted installationNo
Connectable conductor cross section multi-wired0 - 70mm²
Ambient temperature during operating-25 - 60°C
Additional equipment possibleYes
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V36kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V36kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS894001R0405 | S804N-B40

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

690V

Built-in depth

82.5mm

Frequency

50 .. 60Hz

Over voltage category

4

Rated current

40A

Rated insulation voltage Ui

690V

Current limiting class

3

Concurrently switching neutral conductor

Width in number of modular spacings

4

Release characteristic

B

Number of protected poles

4

Number of poles (total)

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Pollution degree

3

Voltage type

AC/DC

Connectable conductor cross section solid-core

0 .. 50mm²

Degree of protection (IP)

IP20

Suitable for flush-mounted installation

Connectable conductor cross section multi-wired

0 .. 70mm²

Ambient temperature during operating

-25 .. 60°C

Additional equipment possible

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

36kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

36kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.