Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth82.5mm
Voltage typeAC/DC
Rated voltage690V
Frequency50 - 60Hz
Rated insulation voltage Ui690V
Release characteristicC
Over voltage category4
Suitable for flush-mounted installationNo
Additional equipment possibleYes
Current limiting class3
Ambient temperature during operating-25 - 60°C
Width in number of modular spacings4
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V36kA
Connectable conductor cross section multi-wired0 - 70mm²
Number of protected poles4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V36kA
Connectable conductor cross section solid-core0 - 50mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Concurrently switching neutral conductorNo
Rated impulse withstand voltage Uimp8kV
Degree of protection (IP)IP20
Pollution degree3
Rated current50A
Number of poles (total)4
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS894001R0504 | S804N-C50

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

82.5mm

Voltage type

AC/DC

Rated voltage

690V

Frequency

50 .. 60Hz

Rated insulation voltage Ui

690V

Release characteristic

C

Over voltage category

4

Suitable for flush-mounted installation

Additional equipment possible

Current limiting class

3

Ambient temperature during operating

-25 .. 60°C

Width in number of modular spacings

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

36kA

Connectable conductor cross section multi-wired

0 .. 70mm²

Number of protected poles

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

36kA

Connectable conductor cross section solid-core

0 .. 50mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Concurrently switching neutral conductor

Rated impulse withstand voltage Uimp

8kV

Degree of protection (IP)

IP20

Pollution degree

3

Rated current

50A

Number of poles (total)

4