Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC/DC
Release characteristicB
Built-in depth82.5mm
Rated current50A
Frequency50 - 60Hz
Rated insulation voltage Ui690V
Rated voltage690V
Over voltage category4
Current limiting class3
Width in number of modular spacings4
Concurrently switching neutral conductorNo
Number of protected poles4
Pollution degree3
Degree of protection (IP)IP20
Suitable for flush-mounted installationNo
Connectable conductor cross section solid-core0 - 50mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Ambient temperature during operating-25 - 60°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V36kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V36kA
Number of poles (total)4
Connectable conductor cross section multi-wired0 - 70mm²
Additional equipment possibleYes
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS894001R0505 | S804N-B50

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC/DC

Release characteristic

B

Built-in depth

82.5mm

Rated current

50A

Frequency

50 .. 60Hz

Rated insulation voltage Ui

690V

Rated voltage

690V

Over voltage category

4

Current limiting class

3

Width in number of modular spacings

4

Concurrently switching neutral conductor

Number of protected poles

4

Pollution degree

3

Degree of protection (IP)

IP20

Suitable for flush-mounted installation

Connectable conductor cross section solid-core

0 .. 50mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Ambient temperature during operating

-25 .. 60°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

36kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

36kA

Number of poles (total)

4

Connectable conductor cross section multi-wired

0 .. 70mm²

Additional equipment possible

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.