Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC
Release characteristicB
Built-in depth69mm
Over voltage category3
Power loss4.8W
Frequency50 - 60Hz
Explosion-proofNo
Current limiting class3
Rated voltage230V
Number of protected poles1
Degree of protection (IP)IP2X
Suitable for flush-mounted installationNo
Pollution degree2
Concurrently switching neutral conductorNo
Connectable conductor cross section multi-wired0 - 25mm²
Connectable conductor cross section solid-core0 - 25mm²
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V6kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Number of poles (total)1
Additional equipment possibleNo
Rated current40A
Width in number of modular spacings1
Ambient temperature during operating-25 - 55°C
Rated insulation voltage Ui440V
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V6kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS211001R0405 | SH201-B40

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC

Release characteristic

B

Built-in depth

69mm

Over voltage category

3

Power loss

4.8W

Frequency

50 .. 60Hz

Explosion-proof

Current limiting class

3

Rated voltage

230V

Number of protected poles

1

Degree of protection (IP)

IP2X

Suitable for flush-mounted installation

Pollution degree

2

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

0 .. 25mm²

Connectable conductor cross section solid-core

0 .. 25mm²

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

6kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Number of poles (total)

1

Additional equipment possible

Rated current

40A

Width in number of modular spacings

1

Ambient temperature during operating

-25 .. 55°C

Rated insulation voltage Ui

440V

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

6kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.