Technical specifications

Frequency50 - 60Hz
Rated current16A
Rated voltage400V
Built-in depth69mm
Release characteristicC
Voltage typeAC
Current limiting class3
Pollution degree2
Concurrently switching neutral conductorNo
Width in number of modular spacings2
Power loss5W
Over voltage category3
Degree of protection (IP)IP20
Number of protected poles2
Explosion-proofNo
Rated insulation voltage Ui440V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Flush-mounted installationNo
Connectable conductor cross section multi-wired0 - 25mm²
Number of poles (total)2
Additional equipment possibleNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V6kA
Connectable conductor cross section solid-core0 - 25mm²
Ambient temperature during operating-25 - 55°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V6kA
Suitable for flush-mounted installationNo
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS212001R0164 | SH202-C16

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Frequency

50 .. 60Hz

Rated current

16A

Rated voltage

400V

Built-in depth

69mm

Release characteristic

C

Voltage type

AC

Current limiting class

3

Pollution degree

2

Concurrently switching neutral conductor

Width in number of modular spacings

2

Power loss

5W

Over voltage category

3

Degree of protection (IP)

IP20

Number of protected poles

2

Explosion-proof

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Flush-mounted installation

Connectable conductor cross section multi-wired

0 .. 25mm²

Number of poles (total)

2

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

6kA

Connectable conductor cross section solid-core

0 .. 25mm²

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

6kA

Suitable for flush-mounted installation

Rated impulse withstand voltage Uimp

4kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.