  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Explosion-proofNo
Built-in depth69mm
Pollution degree2
Frequency50 - 60Hz
Concurrently switching neutral conductorNo
Rated insulation voltage Ui440V
Over voltage category3
Degree of protection (IP)IP20
Current limiting class3
Suitable for flush-mounted installationNo
Power loss9.6W
Connectable conductor cross section solid-core0 - 25mm²
Ambient temperature during operating-25 - 55°C
Additional equipment possibleNo
Connectable conductor cross section multi-wired0 - 25mm²
Flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V6kA
Rated impulse withstand voltage Uimp4kV
Voltage typeAC
Rated current40A
Rated voltage400V
Release characteristicC
Width in number of modular spacings2
Number of protected poles2
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS212001R0404 | SH202-C40

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Explosion-proof

Built-in depth

69mm

Pollution degree

2

Frequency

50 .. 60Hz

Concurrently switching neutral conductor

Rated insulation voltage Ui

440V

Over voltage category

3

Degree of protection (IP)

IP20

Current limiting class

3

Suitable for flush-mounted installation

Power loss

9.6W

Connectable conductor cross section solid-core

0 .. 25mm²

Ambient temperature during operating

-25 .. 55°C

Additional equipment possible

Connectable conductor cross section multi-wired

0 .. 25mm²

Flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

6kA

Rated impulse withstand voltage Uimp

4kV

Voltage type

AC

Rated current

40A

Rated voltage

400V

Release characteristic

C

Width in number of modular spacings

2

Number of protected poles

2

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.