Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth69mm
Voltage typeAC
Rated current20A
Rated voltage400V
Flush-mounted installationNo
Degree of protection (IP)IP20
Power loss10W
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section solid-core0 - 25mm²
Connectable conductor cross section multi-wired0 - 25mm²
Suitable for flush-mounted installationNo
Explosion-proofNo
Frequency50 - 60Hz
Concurrently switching neutral conductorNo
Current limiting class3
Number of protected poles4
Width in number of modular spacings4
Release characteristicC
Over voltage category3
Pollution degree2
Rated insulation voltage Ui440V
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V6kA
Number of poles (total)4
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Additional equipment possibleNo
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V6kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS214001R0204 | SH204-C20

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Voltage type

AC

Rated current

20A

Rated voltage

400V

Flush-mounted installation

Degree of protection (IP)

IP20

Power loss

10W

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section solid-core

0 .. 25mm²

Connectable conductor cross section multi-wired

0 .. 25mm²

Suitable for flush-mounted installation

Explosion-proof

Frequency

50 .. 60Hz

Concurrently switching neutral conductor

Current limiting class

3

Number of protected poles

4

Width in number of modular spacings

4

Release characteristic

C

Over voltage category

3

Pollution degree

2

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

6kA

Number of poles (total)

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Additional equipment possible

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

6kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.