Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth69mm
Voltage typeAC
Release characteristicC
Frequency50 - 60Hz
Rated insulation voltage Ui440V
Rated current40A
Rated voltage400V
Pollution degree2
Current limiting class3
Over voltage category3
Width in number of modular spacings4
Degree of protection (IP)IP20
Connectable conductor cross section solid-core0 - 25mm²
Number of protected poles4
Flush-mounted installationNo
Power loss19.2W
Number of poles (total)4
Ambient temperature during operating-25 - 55°C
Explosion-proofNo
Concurrently switching neutral conductorNo
Additional equipment possibleNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V6kA
Connectable conductor cross section multi-wired0 - 25mm²
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V6kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS214001R0404 | SH204-C40

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Voltage type

AC

Release characteristic

C

Frequency

50 .. 60Hz

Rated insulation voltage Ui

440V

Rated current

40A

Rated voltage

400V

Pollution degree

2

Current limiting class

3

Over voltage category

3

Width in number of modular spacings

4

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

0 .. 25mm²

Number of protected poles

4

Flush-mounted installation

Power loss

19.2W

Number of poles (total)

4

Ambient temperature during operating

-25 .. 55°C

Explosion-proof

Concurrently switching neutral conductor

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

6kA

Connectable conductor cross section multi-wired

0 .. 25mm²

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

6kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.