Built-in depth69mm
Voltage typeAC/DC
Frequency50 - 60Hz
Release characteristicC
Rated insulation voltage Ui440V
Pollution degree2
Width in number of modular spacings1
Current limiting class3
Suitable for flush-mounted installationNo
Over voltage category3
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 55°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Rated impulse withstand voltage Uimp4kV
Connectable conductor cross section multi-wired0 - 25mm²
Additional equipment possibleYes
Connectable conductor cross section solid-core0 - 35mm²
Number of protected poles1
Number of poles (total)1
Rated voltage230V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated current6A
Concurrently switching neutral conductorNo

Recommended products


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS251001R0064 | S201-C6

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Voltage type

AC/DC

Frequency

50 .. 60Hz

Release characteristic

C

Rated insulation voltage Ui

440V

Pollution degree

2

Width in number of modular spacings

1

Current limiting class

3

Suitable for flush-mounted installation

Over voltage category

3

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated impulse withstand voltage Uimp

4kV

Connectable conductor cross section multi-wired

0 .. 25mm²

Additional equipment possible

Connectable conductor cross section solid-core

0 .. 35mm²

Number of protected poles

1

Number of poles (total)

1

Rated voltage

230V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated current

6A

Concurrently switching neutral conductor

From same serie

Recommended products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.