Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Frequency50 - 60Hz
Built-in depth69mm
Pollution degree2
Degree of protection (IP)IP20
Rated insulation voltage Ui440V
Current limiting class3
Over voltage category3
Connectable conductor cross section solid-core0 - 35mm²
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Connectable conductor cross section multi-wired0 - 25mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Ambient temperature during operating-25 - 55°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Rated impulse withstand voltage Uimp4kV
Number of poles (total)1
Number of protected poles1
Release characteristicK
Rated current1A
Voltage typeAC
Additional equipment possibleYes
Width in number of modular spacings1
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Concurrently switching neutral conductorNo
Rated voltage230V
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS251001R0217 | S201-K1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Frequency

50 .. 60Hz

Built-in depth

69mm

Pollution degree

2

Degree of protection (IP)

IP20

Rated insulation voltage Ui

440V

Current limiting class

3

Over voltage category

3

Connectable conductor cross section solid-core

0 .. 35mm²

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Connectable conductor cross section multi-wired

0 .. 25mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated impulse withstand voltage Uimp

4kV

Number of poles (total)

1

Number of protected poles

1

Release characteristic

K

Rated current

1A

Voltage type

AC

Additional equipment possible

Width in number of modular spacings

1

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Concurrently switching neutral conductor

Rated voltage

230V

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.