Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC/DC
Rated voltage230V
Current limiting class3
Over voltage category3
Rated insulation voltage Ui440V
Frequency50 - 60Hz
Built-in depth69mm
Suitable for flush-mounted installationNo
Power loss2.4W
Connectable conductor cross section multi-wired0 - 25mm²
Connectable conductor cross section solid-core0 - 35mm²
Ambient temperature during operating-25 - 55°C
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Flush-mounted installationNo
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Explosion-proofNo
Degree of protection (IP)IP20
Pollution degree2
Rated current3A
Release characteristicZ
Width in number of modular spacings1
Number of protected poles1
Concurrently switching neutral conductorNo
Number of poles (total)1
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS251001R0318 | S201-Z 3

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC/DC

Rated voltage

230V

Current limiting class

3

Over voltage category

3

Rated insulation voltage Ui

440V

Frequency

50 .. 60Hz

Built-in depth

69mm

Suitable for flush-mounted installation

Power loss

2.4W

Connectable conductor cross section multi-wired

0 .. 25mm²

Connectable conductor cross section solid-core

0 .. 35mm²

Ambient temperature during operating

-25 .. 55°C

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Flush-mounted installation

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Explosion-proof

Degree of protection (IP)

IP20

Pollution degree

2

Rated current

3A

Release characteristic

Z

Width in number of modular spacings

1

Number of protected poles

1

Concurrently switching neutral conductor

Number of poles (total)

1

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.