Aleta.hr
Main Product Image

2CDS251001R0401 | S201-D40

Code: 1549083

ManufacturerABB
Catalog number2CDS251001R0401
EAN code4016779530071

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles1
Release characteristicD
Rated current40A
Rated insulation voltage Ui440V
Rated voltage230V
Number of poles (total)1
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Voltage typeAC/DC
Concurrently switching neutral conductorNo
Frequency50 - 60Hz
Current limiting class3
Over voltage category3
Additional equipment possibleYes
Ambient temperature during operating-25 - 55°C
Built-in depth69mm
Width in number of modular spacings1
Connectable conductor cross section multi-wired0 - 25mm²
Connectable conductor cross section solid-core0 - 35mm²
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Suitable for flush-mounted installationNo
Pollution degree2
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS251001R0401 | S201-D40

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles

1

Release characteristic

D

Rated current

40A

Rated insulation voltage Ui

440V

Rated voltage

230V

Number of poles (total)

1

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Voltage type

AC/DC

Concurrently switching neutral conductor

Frequency

50 .. 60Hz

Current limiting class

3

Over voltage category

3

Additional equipment possible

Ambient temperature during operating

-25 .. 55°C

Built-in depth

69mm

Width in number of modular spacings

1

Connectable conductor cross section multi-wired

0 .. 25mm²

Connectable conductor cross section solid-core

0 .. 35mm²

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Suitable for flush-mounted installation

Pollution degree

2

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.